Trees Configuration Model for Hot Humid Tropic Urban Parks Jono Wardoyo; Eko Budihardjo; Eddy Prianto; Muh Nur
RUAS (Review of Urbanism and Architectural Studies) Vol 9, No 2 (2011)
Publisher : RUAS (Review of Urbanism and Architectural Studies)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (584.244 KB) | DOI: 10.21776/ub.ruas.2011.009.02.2

Abstract

Main climatic thermal problems in urban park in hot humid tropic area are how to minimize high solar radiation and to optimize the wind. Trees have potentials in ameliorating urban park microclimate. Trees configuration is one of determining factors to get benefit of vegetation potential in hot humid urban park.Microclimate simulation of 3 (three) different tree configurations in selected urban park model is carried out with three-dimensional numerical model, ENVI-Met V.3.1 which simulates the microclimatic changes within urban environments in a high spatial and temporal resolution. The simulation results show that an east – west orientation tree line configuration model has a higher temperature reduction compared with the base case model.Keywords: Urban park, hot humid tropic, tree configuration model
Redesain Ruang Ibadah Masjid Agung Pati Berdasarkan Performa Kenyamanan Termal, Visual, Dan Akustik ashim furqoni; Eddy Prianto; Agung Budi Sardjono; Gagoek Hardiman
RUAS Vol 20, No 2 (2022)
Publisher : RUAS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21776/ub.ruas.2022.020.02.4

Abstract

Architecture is a place to move comfortably. The mosque is the four worshippers of muslims who should have an optimal level of comfort. This study aims to examine the comfort performance of the prayer room of the Great Mosque of Pati based on applicable theories and standards, then design based on the results of a comfort study to get a prayer room design that meets the comfort criteria for its users. The research was conducted by dividing the prayer room into 16 points. At each point, 3 measurements are carried out, namely thermal, lighting, and noise measurements both in the morning, afternoon, afternoon, and evening. From the measurement results, it is known that the average temperature in the worship room is 27.4 °C, meaning that the temperature is hotter than the standard of comfort (<27 °C). The average exposure is 103.5 lux, meaning the lighting is darker than required (200 lux). The average noise is 61.7 dB, meaning that the situation inside the worship room is noisier than the maximum noise level allowed for the worship space (55 dB).
Redesain Ruang Ibadah Masjid Agung Pati Berdasarkan Performa Kenyamanan Termal, Visual, Dan Akustik ashim furqoni; Eddy Prianto; Agung Budi Sardjono; Gagoek Hardiman
RUAS Vol. 20 No. 2 (2022)
Publisher : Departemen Arsitektur Fakultas Teknik Universitas Brawijaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21776/ub.ruas.2022.020.02.4

Abstract

Architecture is a place to move comfortably. The mosque is the four worshippers of muslims who should have an optimal level of comfort. This study aims to examine the comfort performance of the prayer room of the Great Mosque of Pati based on applicable theories and standards, then design based on the results of a comfort study to get a prayer room design that meets the comfort criteria for its users. The research was conducted by dividing the prayer room into 16 points. At each point, 3 measurements are carried out, namely thermal, lighting, and noise measurements both in the morning, afternoon, afternoon, and evening. From the measurement results, it is known that the average temperature in the worship room is 27.4 °C, meaning that the temperature is hotter than the standard of comfort (<27 °C). The average exposure is 103.5 lux, meaning the lighting is darker than required (200 lux). The average noise is 61.7 dB, meaning that the situation inside the worship room is noisier than the maximum noise level allowed for the worship space (55 dB).